Quarter Turn Actuator
-
Multi Turn Actuator
-
Explosion Proof Electric Actuator
-
Smart Electric Actuator
-
Compact Actuator
-
Fail Safe Electric Actuator
-
Electric Butterfly Valve
-
Electric Actuated Ball Valve
-
3 Phase Actuator
-
DC Rotary Actuator
-
PVC Control Valve
-
Actuator Accessories
-
Valve Bracket
-
Quick Open Electric Actuator
-
Midea Group - ChinaDCL has been our partner and supplier for over 6 years. Their electric actuators are used to drive our guide vane of our refrigeration compressors. Our central air conditioners are serviing customers in HVAC all around the world with DCL's products. They continuously provide very reliable products and very ontime service to support us. -
Valve Solution Inc. - USADCL has been our ODM/OEM plant for about ten years. Their products are designed per UL and CSA standard and passed CSA certification. Very few Chinese manufacturers can produce USA's standard electric actuaotrs with such good quality, that is why we choose them as our long term partner. We are expecting DCL can keep innovation. -
WESA Armaturen GmbH - GermanyWith 15 years cooperation with DCL, we are very satified with DCL's products. DCL regards quality first and their employees are very rigorous to products. They always do many experiments and tests to confirm their new designs and upgrade. We are also amazing about their wonderful quality control for the outsourcing parts.
DCL-Ex Series Explosion-Proof Quarter-Turn Electric Actuator | 50–3000 N·m, IP68, ATEX/IECEx & CSA Class I Div 1
| Standard Torque | 100Nm To 600Nm | Standard Time | 30s To 45s |
|---|---|---|---|
| Total Weight | 5kg To 10kg | Power Supply | 24VAC/110VAV/220VAC/380VAC/24VDC |
| Motor Power | 15W To 90W | Ambient Temperature | -25℃~+55℃ / -13°F~+131°F |
| Installation Angle | 360° | Sealing Grade | IP68 NEMA4X |
-
Standard output torque from 50 to 3000 Nm, with maximum torque from 65 to 3900 Nm.
-
IP68 enclosure and a stated ambient-temperature range of -25°C to +55°C.
-
Explosion-protection markings include Ex db h IIC T4 Gb and Ex h tb IIIC T135°C Db.
-
North American ratings include Class I, Division 1, Groups C and D, T5/T6, and Class I, Zone 1.
-
Available with on-off, position-feedback or modulating control.
-
Modulating versions accept 4–20 mA, 1–5 VDC or 2–10 VDC input and provide 4–20 mA position feedback.
-
Basic modulating error is no more than ±1%, with repeatability error no more than 1%.
-
ISO 5211 direct-mount options and model-dependent DC12V, DC24V, AC110V, AC220V or AC380V power supplies.
-
Optional over-torque protection, anti-condensation heating, Modbus RTU and fail-safe return.
The DCL-Ex Series Explosion-Proof Electric Actuator (models DCL-Ex05 to DCL-Ex300) is a compact quarter-turn actuator designed for automated valve control in oil and gas, petrochemical, chemical, electric power, and metallurgy applications. Delivering standard output torques from 50 to 3000 N·m (maximum torque up to 3900 N·m), the series pairs directly with ball valves, butterfly valves, plug valves, and other compatible rotary valves via ISO5211 mounting interfaces.
Engineered with a die-cast aluminum alloy housing and a round flameproof joint, the DCL-Ex series combines IP68 environmental sealing with an ambient operating temperature range of −25°C to +55°C. Available hazardous-area certifications include:
-
ATEX / IECEx: Ex db h IIC T4 Gb; Ex h tb IIIC T135°C Db
-
CSA (North America): Class I, Division 1, Groups C and D T5/T6; Class I, Zone 1, AEx db IIC T5/T6 Gb; Ex db IIC T5/T6 Gb
-
Additional Compliance: CE, RoHS, CCC, and EAC
Selection Note: Actuator selection must match the site’s gas or dust classification, temperature group, and regional certification requirements. Confirm the exact model, complete explosion-protection marking, and certificate conditions prior to specification. IP68 ingress protection alone does not establish hazardous-area suitability.
The DCL-Ex series supports multiple control circuits to fit standard PLC, DCS, and SCADA architectures:
-
On/Off & Feedback Types (S2 Short-Time Duty, <15 min): Available with active or passive limit switch contacts, 1 kΩ (or 500 Ω) potentiometer feedback, or a 4–20 mA DC position transmitter.
-
Modulating Type (S4 Intermittent Duty, up to 1,200 cycles/hr): Accepts 4–20 mA DC, 1–5 VDC, or 2–10 VDC input signals and outputs 4–20 mA DC position feedback. Features an electronic brake with zero-time damping, adjustable dead space (0.5%–5.0%), basic error ≤±1%, and repeatability error ≤1%.
-
Integrated Modbus-RTU: Models DCL-Ex10 through DCL-Ex300 support an optional multi-functional circuit board integrating on/off control, modulating control, and Modbus-RTU communication in a single unit.
Performance Note: Specified error figures reflect actuator positioning performance rather than the flow-control accuracy of the complete valve assembly.
-
Over-Torque Protection: Interrupts the motor circuit when output torque reaches a preset critical threshold, protecting the valve and gear train during obstruction or jamming.
-
PTC Dehumidifying Heater: Continuously energized internal heater prevents condensation inside the electrical cavity under high humidity or wide diurnal temperature swings.
-
Built-In Battery Fail-Safe Return (DC24V): Integrates all energy-storage components inside the actuator housing (DCL-Ex05 to Ex300) without external battery boxes. Upon external power loss, it drives the valve to a preset safety position—full-open, full-close, or stay-in-place—with a 4 full-stroke drive capacity on a full charge, and automatically resumes normal operation when power is restored.
| Type | Ex05E | Ex10E | Ex20E | Ex40E | Ex60E |
| Power | AC110V/AC220V | ||||
| Output Torque | 50Nm | 100Nm | 200Nm | 400Nm | 600Nm |
| Acting Time | 20S | 30S | 30S | 30S | 45S |
| Turning Angle | 0-90° | 0-90° | 0-90° | 0-90° | 0-90° |
| Motor Power | 10W | 25W | 40W | 90W | 90W |
| Rated Current | 0.24/0.15A | 0.57/0.30A | 0.63/0.35A | 1.12/0.64A | 1.18/0.67A |
| Total Weight | 3.0kg | 5.0kg | 5.5kg | 9.5kg | 10.0kg |
| Input Signal | 4-20mADC,1-5VDC,2-10VDC | ||||
| Output Singal | 4-20mADC | ||||
| Basic Error | not more than ±1% | ||||
| Reciprocating Error | not more than 1% | ||||
| Dead Space | 0.5%-5.0% adjustable | ||||
| Damping Characteristic | 0 times | ||||
| Repeating Error in Actuator | ≤1% | ||||
| Insulating Resistance | 100MΩ/500VDC | ||||
| Withstand Voltage Class | 1500VAC 1minutes | ||||
| Protection Class | IP68 | ||||
| Explosive-proof grade | Exd II CT4Gb | ||||
| Installation Angle | 360°at any angle | ||||
| Electric Interface |
2-M20*1.5 explosion-proof plug,clients should install corresponding explosion-proof cable connector when using according to the cable selected. |
||||
| Ambient Temperature | -20℃~+60℃ | ||||
| Optional Function | Over-torque protector/Dehumidify Heater/Passive contact switch | ||||
| Remark | Any other input or output signal needed, please specified in purchase order. | ||||
![]()
![]()