Quarter Turn Actuator
-
Multi Turn Actuator
-
Explosion Proof Electric Actuator
-
Smart Electric Actuator
-
Compact Actuator
-
Fail Safe Electric Actuator
-
Electric Butterfly Valve
-
Electric Actuated Ball Valve
-
3 Phase Actuator
-
DC Rotary Actuator
-
PVC Control Valve
-
Actuator Accessories
-
Valve Bracket
-
Quick Open Electric Actuator
-
Midea Group - ChinaDCL has been our partner and supplier for over 6 years. Their electric actuators are used to drive our guide vane of our refrigeration compressors. Our central air conditioners are serviing customers in HVAC all around the world with DCL's products. They continuously provide very reliable products and very ontime service to support us. -
Valve Solution Inc. - USADCL has been our ODM/OEM plant for about ten years. Their products are designed per UL and CSA standard and passed CSA certification. Very few Chinese manufacturers can produce USA's standard electric actuaotrs with such good quality, that is why we choose them as our long term partner. We are expecting DCL can keep innovation. -
WESA Armaturen GmbH - GermanyWith 15 years cooperation with DCL, we are very satified with DCL's products. DCL regards quality first and their employees are very rigorous to products. They always do many experiments and tests to confirm their new designs and upgrade. We are also amazing about their wonderful quality control for the outsourcing parts.
CSA ATEX Over-Torque Protection AC110/220V 200Nm 30S Explosion Proof Electric Actuator
| Standard Torque | 100Nm To 600Nm | Standard Time | 30s To 45s |
|---|---|---|---|
| Total Weight | 5kg To 10kg | Power Supply | 24VAC/110VAV/220VAC/380VAC/24VDC |
| Motor Power | 15W To 90W | Ambient Temperature | -25℃~+55℃ / -13°F~+131°F |
| Installation Angle | 360° | Sealing Grade | IP68 NEMA4X |
- Quarter turn operation with mechanical limits
- Heavy duty motor with thermal overload protection
- Rugged IP68/NEMA 4X aluminum alloy housing with powder coating
- Explosion proof grade ExdIICT4 for Zone system and Group C, D T4 for Division system
- Over torque protection is available
- Anti-condensation heater is optional
- Standard ISO5211 direct installation
- Manual override with Allen wrench or handwheel
- CSA certification
- Update:The DC12V power supply models DCL-Ex05, DCL-Ex10 and DCL-Ex20 have obtained CSA certification.
DCL explosion-proof electric actuators provide valve automation for hazardous industrial environments. Optional over-torque protection, motor thermal protection, and flameproof enclosure construction address mechanical overload, abnormal motor heating, and ignition containment.
Optional Over-Torque Protection
Crystallization, deposits, or foreign particles can restrict valve movement and increase operating torque. With the optional built-in over-torque protection system, a torque switch interrupts motor power when output torque reaches the preset threshold. This helps limit excessive mechanical loading on the valve stem and actuator gearing.
The protection setting should be matched to the valve assembly’s allowable torque. It does not remove obstructions or replace inspection after a protective shutdown.
Motor Thermal Protection
PTC thermal protectors embedded in the motor windings provide protection against abnormal temperature rise. The protection circuit interrupts motor power when winding temperature reaches 105°C and resets after cooling to approximately 80–90°C.
Torque protection responds to excessive output torque, while thermal protection responds to motor temperature. These complementary functions address different overload conditions. Subsequent operation after a thermal reset depends on the control configuration and operating command.
Flameproof Enclosure Construction
The motor, electronic component, and terminal compartments incorporate flameproof construction, with precision-machined joints at critical enclosure interfaces.
Controlled joint clearances and engagement lengths form part of the flameproof design, helping prevent an internal ignition from propagating to the surrounding explosive atmosphere. The die-cast aluminum alloy enclosure provides the structural housing for this protection system.
Selected configurations are intended for explosive gas or combustible dust atmospheres, excluding underground coal mine applications. Suitability must be checked against the applicable gas or dust protection marking.
Enclosure Protection and Certification
DCL explosion-proof actuator specifications list IP68 enclosure protection and CSA certification for applicable North American hazardous locations, including Class I, Division 1 and Class I, Zone 1 configurations.
Selection should follow the exact certification marking for the supplied model, including gas group, temperature class, ambient limits, and installation requirements. Where immersion is expected, confirm the permitted depth and duration separately.
| Type | Ex05E | Ex10E | Ex20E | Ex40E | Ex60E |
| Power | AC110V/AC220V | ||||
| Output Torque | 50Nm | 100Nm | 200Nm | 400Nm | 600Nm |
| Acting Time | 20S | 30S | 30S | 30S | 45S |
| Turning Angle | 0-90° | 0-90° | 0-90° | 0-90° | 0-90° |
| Motor Power | 10W | 25W | 40W | 90W | 90W |
| Rated Current | 0.24/0.15A | 0.57/0.30A | 0.63/0.35A | 1.12/0.64A | 1.18/0.67A |
| Total Weight | 3.0kg | 5.0kg | 5.5kg | 9.5kg | 10.0kg |
| Input Signal | 4-20mADC,1-5VDC,2-10VDC | ||||
| Output Singal | 4-20mADC | ||||
| Basic Error | not more than ±1% | ||||
| Reciprocating Error | not more than 1% | ||||
| Dead Space | 0.5%-5.0% adjustable | ||||
| Damping Characteristic | 0 times | ||||
| Repeating Error in Actuator | ≤1% | ||||
| Insulating Resistance | 100MΩ/500VDC | ||||
| Withstand Voltage Class | 1500VAC 1minutes | ||||
| Protection Class | IP68 | ||||
| Explosive-proof grade | Exd II CT4Gb | ||||
| Installation Angle | 360°at any angle | ||||
| Electric Interface | 2-M20*1.5 explosion-proof plug,clients should install corresponding explosion-proof cable connector when using according to the cable selected. | ||||
| Ambient Temperature | -20℃~+60℃ | ||||
| Optional Function | Over-torque protector/Dehumidify Heater/Passive contact switch | ||||
| Remark | Any other input or output signal needed, please specified in purchase order. | ||||
![]()
![]()